US Motors' "Shur-Stop Brake Kits" come in seven different foot pounds and only fit a selected types of motors up to seven frame sizes right off the shelf. They use Stearns brakes and US Motors' proprietary adapter bracket and hub assemblies to fit these certain motor types. Types : FUT, UTE, UTI, UTF, UT, UTP, TMP and UTIP.
There are a few variations of this that we can physically modify to fit older versions but for the most part these are the "Off The Shelf" standards. 1.5 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC
3 foot pounds 115/230v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC 3 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC 3 foot pounds 575v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC
6 foot pounds 125/250v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC 6 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC 6 foot pounds 575v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC
10 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 56, 56C and 140TC
10 foot pounds 125/250v FUT, UTE, UTI, UTF, UT, UTP, TMP 180T and 180TC 10 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 180T and 180TC 10 foot pounds 575v FUT, UTE, UTI, UTF, UT, UTP, TMP 180T and 180TC
15 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 180T and 180TC 15 foot pounds 575v FUT, UTE, UTI, UTF, UT, UTP, TMP 180T and 180TC
25 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 210T and 210TC 35 foot pounds 230/460v FUT, UTE, UTI, UTF, UT, UTP, TMP 210T and 210TC
Notes : 1. All 230/460v (60Hz) brakes are nameplated and designed for use on 190/380 Vac, 50Hz rated at ft-lb per above.
2. All 125/250v (60Hz) brakes are suitable for 160/220 Vac, 50Hz at ft-lb per above.
3. Acceptable mounting positions are noted below. (From horizontal motor and brake solenoid position to - Degrees from Vertical) 1.5, 3, 6 foot pounds good for 0, 60, 120, 180, 240, 300 degrees 10, 15 foot pounds good for 0, 60, 120, 180, 240, 300 degrees 25, 35 foot pounds good for 0, 60, 300 degrees
4. Motor and Brake Vertical Rules 1.5, 3, 6 foot pounds - Brake High = OK, Brake Low = OK 10, 15 foot pounds - Brake High = OK, Brake Low = OK 25, 35 foot pounds - Brake High = NOT OK (additional kit needed), Brake Low = OK 5. These kits are only rated at 1 start/stop per minute when used in conjunction with a Motor and Reducer. 6. When shorter cycles of Start/Stop are required please call us and let us help you figure out what will better suit your needs. We may offer a Leroy Somer "Brake Motor" that can offer more cycles to suit you better.
7. If using Inverter on the motor to above 1750rpm at 60Hz be aware that your typical wear items will wear faster due to higher friction and physical stopping force.
8. The lower the RPM of the motor, the more Foot Pounds of stopping power you need.
We want you to be happy with the product. We do not want you to be blind sided by factors that may not have been considered.
|
|